Restore cooling efficiency, eliminate foul odors, and reduce electricity consumption with specialized AC servicing. We use waterproof service jackets and precision jet pressure washers to flush evaporator coils, clean blower fan wheels, and clear algae from condensate lines without splashing your walls.
Understanding the difference between standard dry servicing, jet pump wet wash, and chemical foam cleaning.
Best For: Light maintenance midway through the season.
Scope: High-velocity air blower dusting, washing mesh air filters under water, wiping plastic louvers, cleaning drain tray outlet, and checking cooling airflow.
Limitation: Does not penetrate compacted grime deep inside the aluminium fins.
Best For: Pre-summer startup and post-monsoon maintenance.
Scope: The technician fits a waterproof service apron around the indoor unit. A high-pressure electric jet pump flushes dirt, mold, and dust from deep within the cooling fins and blower wheel into a bucket.
Result: Dramatically boosts airflow and heat exchange efficiency.
Best For: ACs producing foul odors, musty vinegar smells, or units near kitchens.
Scope: Biodegradable chemical foam is sprayed over the evaporator and blower fan. The foam expands, dissolving greasy cooking residues and killing bacterial colonies, followed by pressurized water rinsing.
Result: Fresh, sanitary air and long-lasting coil hygiene.
Every service visit covers critical mechanical, electrical, and airflow safety parameters.
• Filter Wash: Removing micro-dust mats from nylon pre-filters.
• Evaporator Coil Wash: Cleaning fins with balanced water pressure to avoid bending copper tubing.
• Blower Wheel De-greasing: Scrubbing the cylindrical squirrel-cage blower to eliminate vibration and restore air throw.
• Condensate Drain Pipe Flush: Forcing water through the drain pipe to clear algae blockage.
• Louver & Motor Gear Check: Ensuring smooth horizontal and vertical swing action.
• Temperature Differential Test: Measuring delta T between intake air and outlet air (optimal 8°C–12°C).
• Condenser Coil Flush: Power washing outdoor coil fins to strip exterior mud, street dust, and pollution.
• Fan Blade Balance: Checking outdoor propeller fan for balance, shaft play, and bearing noise.
• Terminal & Contactor Tightening: Inspecting high-voltage screw terminals to prevent loose wire arcing.
• Operating Current Measurement: Measuring running amperes using a digital clamp meter to confirm proper load.
• Vibration Pad Inspection: Checking rubber dampers under compressor legs to prevent resonance humming.
• Refrigerant Pressure Verification: Checking operating suction pressure without unnecessary tampering.
Straightforward, transparent service charges with zero hidden fees.
| Service Package | Procedures Included | Indicative Price Range | Best Suited For |
|---|---|---|---|
| Standard Dry AC Service | Filter washing, high-velocity blower dusting, drain tray flush, operational check | ₹449 - ₹699 | Mid-season touch-up, low-dust bedrooms. |
| Jet Pump Wet Servicing (Split AC) | Waterproof apron jacket, high-pressure jet wash on indoor & outdoor coils, blower wheel wash | ₹899 - ₹1,299 | Pre-summer startup, high-traffic living rooms, urban apartments. |
| Anti-Bacterial Foam Jet Servicing | Specialized chemical foam treatment, mold disinfection, pressure rinse, deodorizing | ₹1,199 - ₹1,599 | ACs with musty mold smells, kitchens, allergy-sensitive households. |
| Window AC Jet Clean (Full Pull-out) | Chassis removal, base tray scrubbing, rust treatment, pressure wash of both coils | ₹699 - ₹999 | Window ACs showing rust, dirty drain pans, or low cooling. |
| Annual Maintenance Contract (AMC - Basic) | 2 scheduled wet jet services + 2 dry services + priority breakdown labour visits | ₹1,999 - ₹3,499 / year | Residential homes wanting hassle-free seasonal maintenance. |
Answers to common customer questions regarding service frequency, wet washing, and energy savings.
No. Professional technicians use a specialized waterproof AC service apron jacket that fits securely around the indoor unit. All water and dirt flushed by the pressure washer are channeled directly into a sealed drainage tube leading into a wastewater bucket, keeping your walls and floor dry.
A dirty, clogged air conditioner forces the compressor to run up to 30% longer to achieve the same cooling result because heat exchange across the insulated coils is restricted. Thorough cleaning can reduce power consumption by 15% to 25%, noticeably lowering monthly power bills.
In most Indian cities with construction and road dust, mesh pre-filters should be removed and rinsed under tap water every 2 to 3 weeks during peak summer usage. This simple 5-minute task maintains good airflow and prevents dust from settling deep into the cooling fins.
A sour vinegar smell is caused by bacterial colonies and mold growing in the damp, dark environment of the evaporator cooling fins and stagnant water in the drain tray. An anti-bacterial foam treatment dissolves this biofilm and sanitizes the air path.
Yes. If the outdoor unit is safely accessible from a balcony, wide window ledge, or terrace, technicians use compact pressure washers. If the unit is mounted flush on a multi-story exterior wall without ledge access, specialized safety harnesses or exterior boom platforms may be required.
No. Servicing is preventive mechanical and thermal maintenance. Refrigerant gas is contained in a hermetically sealed closed loop. If gas pressure is low, it indicates a physical leak that requires diagnostic leak testing, brazing, and vacuuming, which is a repair service.
A proper jet pump wet service typically takes 45 to 60 minutes for a single split AC. This includes setting up the waterproof apron, foaming, pressure rinsing both indoor and outdoor coils, flushing the drain line, and validating temperature drops.
Neglecting service leads to high head pressure on the compressor, causing it to overheat and trip repeatedly. It also promotes coil corrosion, water leakage into the room due to algae-clogged drain pipes, and poor air quality harboring fungal spores.
Yes, provided HVAC-formulated, pH-balanced coil cleaners are used. Our technicians use non-corrosive, biodegradable foaming agents that dissolve grease and dust without eroding hydrophilic coatings or pitting aluminium fins.
An Annual Maintenance Contract (AMC) schedules quarterly preventive visits and provides priority breakdown callouts. For offices, retail stores, and clinics where ACs run 10–14 hours daily, AMCs prevent expensive work disruptions and maintain compliance with indoor air quality requirements.
Yes. For a window AC, the technician slides the chassis out of its outer wall sleeve onto a wash stand or service area. Both the indoor evaporator and outdoor condenser coils are pressure-washed, the base pan is scraped clean of rust and mud, the blower wheel is scrubbed, and fan motor bearings are lubricated before reinstalling the unit.
In coastal zones and industrial corridors, salt mist and acidic fumes pit copper U-bends and corrode aluminum fins. Regular bi-monthly freshwater rinsing removes deposited salt crusts. Applying anti-corrosive polyurethane or epoxy protective spray coats over coil headers significantly extends condenser lifespan.
Connect with verified local technicians equipped with jet wash kits in your area.